Fire Alarm Systems; These are early warning systems against factors that endanger human health and life. They are the most important of the security needs of buildings as they are directly related to life health. Fire alarms are found in offices, factories, workplaces, homes and public buildings. They continue to work as a part of daily life.

Regardless of the detection method, if the alarm is triggered, the sirens will work to alert and evacuate people in the building that there may be a fire. The fire alarm system may also include a remote signal system that alerts the fire department via a central station.


When smoke or heat is detected in the environment, the central panels switch to alarm and activate the sounders. After this, the building's fire or gas detection sounders will sound and sound. An alarm is also generated at the central control unit.


The building doors / turnstiles are released after this triggering. Depending on where the detection is made, the fire-separating doors are released and the fire, if any, is prevented from passing to other areas of the building.


They are generally designed in 2 different types;

  • Addressable Fire Alarm Systems
    • In addressable fire alarm systems, each connected element has an address. Therefore, the user can see from which detector or warning button an alarm is triggered via the fire alarm panel. In this way, users can see which room on which floor is alarmed and reach the scene in a shorter time.
  • Conventional Fire Alarm Systems
    • Conventional fire alarms can collect sensors and alarm buttons in certain groups (Zone) to indicate from which zone the alarm is issued. This requires the user to navigate the sensors and the warning buttons within the zone.

Fire Alarm Systems

Solo 330, Aerosol Dispenser
Please Ask
Brand: Solo Model: Solo-330-001
Solo 330, Aerosol DispenserCodes and standards require functional tests to introduce (simulated) smoke through the detector vents and into the sensing chamber. The Solo 330 dispenser is the most popular device for achieving this, benefiting as it does, from a cup big enough for the great majority of..
Solo A5 Smoke Detector Tester
Hot
Brand: Solo Model: SOLO-A5-001
Solo A5 Smoke Detector TesterSmoke Detector TestingRequirements for testing of smoke detectors vary by country, the common need is for a functional test where smoke, or simulated smoke, is introduced through the vents of the detector to the sensor.Functional testing is required by all national stand..
FAS-420-TT1, Aspirating Smoke Detector(1 Detector) FAS-420-TT1, Aspirating Smoke Detector(1 Detector)
Please Ask
Brand: Bosch Model: FAS-420-TT1
FAS-420-TT1, Aspirating Smoke Detector(1 Detector) The FAS‐420 Series Aspirating Smoke Detectors are specially designed for direct connection to the Local SecurityNetwork LSN improved version with the extended features. They are active fire detection systems for early fire detection in area and equ..
FLM‐420‐NAC-S, Signaling Device Interface Modules FLM‐420‐NAC-S, Signaling Device Interface Modules
Please Ask
Brand: Bosch Model: FLM‐420‐NAC-S
FLM‐420‐NAC-S, Signaling Device Interface ModulesWith 1 supervised output line for conventional signaling devices, with surface-mounted housingFLM‐420‐NAC Signaling Device Interface Modules make it possible to monitor and activate a group of signaling devices (NAC = Notification Appliance Circuit) i..
Brand: Bosch Model: ROLP-W-LX-W-WF
ROLP-W-LX-W-WF, LX Sounder Beacons ConventionalThe LX Sounder Beacons are for dual use applications where a visual alarm device is required in addition to an audible alarm.FunctionsThe device has a unique lens design to achieve the required illumination specified by EN54-23. The flash rate as well a..
GD-870S, White Body, Wall Type Door Holder, 24VDC GD-870S, White Body, Wall Type Door Holder, 24VDC
Hot Please Ask
Brand: Gianni Model: GD-870S
GD-870S, White Body, Wall Type Door Holder, 24VDC..
Brand: Horing Lih Model: AH-03127-BS
AH-03127-BS, Flashing Fire Alarm SirenThis electronic sounder is designed for use with fire alarm systems, security systems and industrial signaling systems. Combined sounder and beacon provides an audio-visual warning which is suitable for places where high sound output and visual indication is req..
Brand: Bosch Model: FNM-320LED-SRD
FNM-320LED-SRD, Flashing Fire Alarm SirenMain Features112 dB (A) maximum sound levelCompact, durable and maintenance-freeSuitable for bad environmental conditionsSound-light warning device combined with integrated LED..
D-296, 24V Beam Type Smoke Detector
Out Of Stock
Brand: Bosch Model: D-296
D-296, 24V Beam Type Smoke DetectorOperates over distances between 30 ft (9 m) and 350 ft (107 m)Six levels of switch-selectable sensitivityBuilt-in alignment sights and tamper protectionAutomatic range adjustment, signal synchronization, and contamination adjustmentRemote indicator plate annunciate..
VTB-32-DB-W, Low Current Sounder/Beacon
Hot
Brand: Cranford Model: VTB-32-DB-W
VTB-32-DB-W, Low Current Sounder/BeaconAll units are available with either Red or Amber lens arrangements as standard.Tone and volume are selected via DIL switches on the PCB. If required, the use of a third wire enables a second stage alarm to be switched in to override that selected tone.Standard ..
Showing 25 to 36 of 72 (6 Pages)