Your Cart
Internet cookies are used to allow personalized pages to be presented to make your visit more convenient and quick to your personal needs. Click for detailed info.


Fire Alarm Systems; These are early warning systems against factors that endanger human health and life. They are the most important of the security needs of buildings as they are directly related to life health. Fire alarms are found in offices, factories, workplaces, homes and public buildings. They continue to work as a part of daily life.

Regardless of the detection method, if the alarm is triggered, the sirens will work to alert and evacuate people in the building that there may be a fire. The fire alarm system may also include a remote signal system that alerts the fire department via a central station.


When smoke or heat is detected in the environment, the central panels switch to alarm and activate the sounders. After this, the building's fire or gas detection sounders will sound and sound. An alarm is also generated at the central control unit.


The building doors / turnstiles are released after this triggering. Depending on where the detection is made, the fire-separating doors are released and the fire, if any, is prevented from passing to other areas of the building.


They are generally designed in 2 different types;

  • Addressable Fire Alarm Systems
    • In addressable fire alarm systems, each connected element has an address. Therefore, the user can see from which detector or warning button an alarm is triggered via the fire alarm panel. In this way, users can see which room on which floor is alarmed and reach the scene in a shorter time.
  • Conventional Fire Alarm Systems
    • Conventional fire alarms can collect sensors and alarm buttons in certain groups (Zone) to indicate from which zone the alarm is issued. This requires the user to navigate the sensors and the warning buttons within the zone.

Fire Alarm Systems

FPE-8000-FMR, Avenar Remote Keypad FPE-8000-FMR, Avenar Remote Keypad
New
Brand: Bosch Model: FPE-8000-FMR
FPE-8000-FMR, Avenar Remote Keypad The remote keypad allows decentralized operation of a fire safety system. The design of the graphical user interface is identical to the fire panels. A color display shows all messages. The touch screen is for operation of a specific panel or the entire system. Th..
Brand: Bosch Model: FAP-425-DOT-R
FAP-425-DOT-R, Addressable Optical Smoke + Thermal Detector Analog addressable detector with two optical sensors, one thermal sensor, manually and automatically addressable.Detection Area: 120 m² Max. Installation Height: 16mAVENAR detector 4000 is a new range of automatic fire detect..
Brand: Bosch Model: FAP-425-DO-R
FAP-425-DO-R, Interactive Optical Smoke Detector Bosch, Analog addressable detector with two optical sensor, manually and automatically addressable.Detection Area: 120 m²Max. Installation Height: 16mAVENAR detector 4000 is a new range of automatic fire detectors featuring a superb a..
Brand: Bosch Model: FAP-425-OT-R
FAP-425-OT-R, Auto-addressable Optic/Thermal Detector Analog addressable detector with one optical and one thermal sensor, automatic and manual address setting.Detection Area: 120m² Max. Installation Height: 16mAVENAR detector 4000 is a new range of automatic fire detectors featuring ..
Brand: Bosch Model: FAP-425-O-R
FAP-425-O-R, Interactive Optical Smoke Detector Bosch, Analog addressable detector with one optical sensor, manually and automatically addressable.Detection Area: 120 m²Max. Installation Height: 16mAVENAR detector 4000 is a new range of automatic fire detectors featuring a superb ac..
FAS-420-TT1, Aspirating Smoke Detector(1 Detector)
Please Ask
Brand: Bosch Model: FAS-420-TT1
FAS-420-TT1, Aspirating Smoke Detector(1 Detector) The FAS‐420 Series Aspirating Smoke Detectors are specially designed for direct connection to the Local SecurityNetwork LSN improved version with the extended features. They are active fire detection systems for early fire detection in area and equ..
Brand: Bosch Model: FLM‐420‐NAC-S
FLM‐420‐NAC-S, Signaling Device Interface ModulesWith 1 supervised output line for conventional signaling devices, with surface-mounted housingFLM‐420‐NAC Signaling Device Interface Modules make it possible to monitor and activate a group of signaling devices (NAC = Notification Appliance Circuit) i..
ROLP-R-LX-W-WF, LX Sounder Beacons Conventional ROLP-R-LX-W-WF, LX Sounder Beacons Conventional
Hot
Brand: Bosch Model: ROLP-R-LX-W-WF
ROLP-R-LX-W-WF, LX Sounder Beacons ConventionalThe LX Sounder Beacons are for dual use applications where a visual alarm device is required in addition to an audible alarm.FunctionsThe device has a unique lens design to achieve the required illumination specified by EN54-23. The flash rate as well a..
Brand: Horing Lih Model: AH-03127-BS
AH-03127-BS, Flashing Fire Alarm SirenMain Features32 signal tones selectable by Dip switch.High sound output with low current consumption.High efficiency lens for maximum light output.Volume Control as standard.Two sets of IN and OUT terminals, easy for installation...
Brand: Bosch Model: FNM-320LED-SRD
FNM-320LED-SRD, Flashing Fire Alarm SirenMain Features112 dB (A) maximum sound levelCompact, durable and maintenance-freeSuitable for bad environmental conditionsSound-light warning device combined with integrated LED..
D-296, 24V Beam Type Smoke Detector
Out Of Stock
Brand: Bosch Model: D-296
D-296, 24V Beam Type Smoke DetectorOperates over distances between 30 ft (9 m) and 350 ft (107 m)Six levels of switch-selectable sensitivityBuilt-in alignment sights and tamper protectionAutomatic range adjustment, signal synchronization, and contamination adjustmentRemote indicator plate annunciate..
Showing 1 to 12 of 50 (5 Pages)